ComponentSpecificationCode or standardWhy it is here
Solar array13.8 kW DC
ModulesREC Alpha Pure-R, 430 W, 32 modulesUL 61730Lead-free cells and a 25-year product warranty, so the panel warranty outlasts the roof underlayment beneath it.
RackingIronRidge XR10 rail on L-foot attachments, 48 in spansUL 2703XR10 carries the span this roof plane needed without adding a third rail run, which keeps the number of roof penetrations down.
FlashingIronRidge FlashFoot2, one per attachmentIRC R905.2.8Every penetration gets a flashed mount rather than a sealant-only bracket. Sealant is the first thing to fail in Texas heat.
Electrical and interconnection200 A service
MicroinvertersEnphase IQ8M, one per moduleUL 1741 SA, IEEE 1547Per-module conversion means one shaded or failed panel does not drag down a whole string, and it keeps DC off the roof.
Rapid shutdownModule-level, initiated at the AC disconnectNEC 690.12Required so a fire crew can de-energise the array from the ground.
InterconnectionLoad-side breaker into the existing 200 A panelNEC 705.12(B)The panel had the busbar headroom for a load-side tie, which avoided a service upgrade and the Austin Energy wait that comes with one.
Battery storage40.5 kWh
BatteriesTesla Powerwall 2, 13.5 kWh AC, 3 unitsUL 9540AC-coupled, so the batteries sit downstream of the microinverters and the array keeps producing during an outage.
Backup gatewayTesla Backup Gateway 2, whole-home backupUL 1741Handles the grid disconnect on an outage. Whole-home rather than a critical-loads subpanel because 40.5 kWh carries this house overnight.

IRC 2021, as adopted by the City of Austin · IFC 2021 · NEC 2020, adopted statewide.

What they asked, and what we told them

What they asked

Do I need a new roof before panels?

What we told them

Yes. Yours had 4 years left, so we re-roofed first. That added $14k and six weeks before solar could start.